Slide to fit
Driver
Figure 41: Slide driver-half of coupling guard towards motor
10. Use a nut, a bolt, and two washers to secure the coupling guard halves together.
11. Tighten all nuts on the guard assembly.
5.6.2 Bearing lubrication
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. Ensure
bearings are properly lubricated prior to startup.
NOTICE:
Grease can settle in equipment left idle leaving bearings improperly lubricated. Check the
greasing on a pump that has been out of service for a long period of time and re-grease if nec-
essary.
Pumps are shipped without oil. You must lubricate oil-lubricated bearings at the job site.
Grease-lubricated bearings are lubricated at the factory.
The bearing manufacturer fills greased-for-life bearings with grease and seals them at the factory. You do
not need to lubricate or seal these bearings.
5.6.2.1 Oil volumes
Oil volume requirements
This table shows the required amount of oil for oil-lubricated bearings.
Frame
ml
Qts.
Oz.
STi
400
0.5
16
MTi
1400
1.5
47
LTi
1400
1.5
48
XLT-i and i17
3000
3
96
5.6 Couple the pump and driver
58
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual