6.4.7.2 Remove the impeller (XLT-i, and i17)
WARNING:
Risk of severe physical injury or death from explosion of trapped liquid. Never use heat to re-
move parts unless explicitly stated in this manual.
CAUTION:
Risk of physical injury from sharp edges. Wear heavy work gloves when handling impellers.
Clamp the frame foot (241) to the workbench when you use this method to remove the impeller.
1.
Remove the impeller plug (458Y) from the front of the impeller (101) and discard the PTFE gasket
(428D).
428D
458Y
2.
Spray penetrating oil through the plug hole into the cavity at the end of the shaft and let it penetrate
for 15 minutes.
3.
While waiting, rotate the shaft several times to distribute the oil.
4.
Slide the shaft wrench (A05107A) over the shaft (122) and key.
5.
Rotate the impeller clockwise (viewed from the impeller end of the shaft) and raise the wrench off of
the work surface.
6.
To loosen the impeller, quickly turn the impeller counter-clockwise (viewed from the impeller end of
the shaft) while impacting the wrench handle on the workbench or a solid block.
7.
Repeat step 6 until the impeller becomes loose.
8.
If step 6 and 7 do not work then do this:
a) Place a socket wrench over the cast nut on the impeller hub.
b) Turn the impeller counter-clockwise (viewed from the impeller end of the shaft).
Be sure that the impeller wrench rests on the workbench or a solid block and that the power end is
secure on the work surface.
9.
Remove and discard the impeller O-ring (412A).
You will insert a new O-ring during reassembly.
6.4 Disassembly
82