Magnet
761B
Figure 46: i-ALERT
®
Health monitor activation
When the condition monitor is activated it:
1.
Displays a series of red LEDs followed by a solid green LED.
2.
Collects eight samples that are spaced one second apart.
3.
Averages these readings to establish the baseline vibration level.
4.
Flashes a green LED after approximately twelve seconds.
For the first ten minutes, the green LED flashes every second for five consecutive flashes and then paus-
es to take a vibration reading. More frequent measurements (every six seconds) are taken in this startup
period so that an alarm can be immediately detected.
5.12 i-ALERT
®
2 Equipment Health Monitor
WARNING:
Explosive hazard and risk of personal injury. Heating to high temperatures could cause com-
bustion of the condition monitor. Never heat the condition monitor to temperatures in excess of
149°C | 300°F or dispose of in a fire.
For all information refer to the i-ALERT
®
2 Equipment Health Monitor Installation, Operation and Mainte-
nance manual.
http://www.ittproservices.com/aftermarket-products/monitoring/i-alert2/i-ALERT2.com
5.13 Pump operation precautions
General considerations
NOTICE:
•
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow
from the suction side. This action can result in decreased performance, unexpected heat
generation, and equipment damage.
5.12 i-ALERT®2 Equipment Health Monitor
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
67