SCALE
0.150
Figure 114: Remove impeller and shaft sleeve
4.
Check the frame-face run-out by rotating the shaft so that the indicator measures the fit for 360º.
If the total indicator reading is greater than 0.025 mm | 0.001 in., then disassemble and determine
the cause.
Figure 115: Check frame-face run-out
5.
Place the manila gasket (360D) on the frame (228), and hold the gasket in place by inserting the
dowel pins (469B) in their holes.
The gasket is designed to fit only one way.
6.
Install the frame adapter.
a) Place the frame adapter (108) onto the frame assembly.
b) Align the bolt holes and dowel locations on the frame adapter with the bolt holes and dowel lo-
cations on the frame.
6.6 Reassembly
128
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual