Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
1
3
4
5
2
Item
Description
1.
Bolt Retainer, 2 required
2.
Shaft Guard Half, 2 required
3.
5/16-18 x .62 in. Hex Flange Screw, 2 required – shaft guard half to bracket
4.
Bracket Assembly, 2 required
5.
1/4-20 x .50 in. Hex Flange Screw, 4 required – bracket to frame adapter
Figure 132: Required parts (MTi/LTi/XLTi/i17)
1.
Ensure that the mounting bolt for each shaft guard half is inserted with the bolt retainer in place for
captive hardware.
2.
If brackets were removed during disassembly, attach brackets to the frame adapter on each side of
the pump.
3.
Assemble a guard half from each side of the pump and fasten to the bracket connection.
4.
Ensure that adequate coverage is maintained for rotating components.
Figure 133: Shaft guard assembly
6.6 Reassembly
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
141