370H
184
Figure 127: Seal-chamber cover or backplate installation
b) Check the seal-chamber cover runout.
Figure 128: Check seal-chamber cover runout
Rotate the indicator through 360 degrees. If the total indicator reading is greater than 0.13 mm |
0.005 in., determine the cause and correct the issue before you proceed.
c)
Install the shaft sleeve (126).