184
355
250
370H
Figure 59: Seal chamber cover removal
4.
Remove the shaft sleeve (126) if it is used.
The mechanical seal is attached to the sleeve.
NOTICE:
Be careful with the mechanical seal. Carbon or ceramic components are brittle and easily bro-
ken.
5.
Remove the rotary portion of the seal from the sleeve by loosening the setscrews and sliding it off
the sleeve.
Refer to the mechanical-seal instructions for more information.
6.
Remove the gland (250), the stationary portion of the seal, and the O-ring (360Q).
126
383
360Q
383
250
Figure 60: Gland removal
6.4.11 Remove the stuffing-box cover (3196, CV 3196, HT 3196, LF 3196,
3796)
1.
Remove the gland nuts (355) and the gland (107).
2.
Remove the stuffing-box-cover nuts (370H).
3.
Remove the stuffing-box cover (184).
6.4 Disassembly
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
85