•
oil-cooler inlet and outlet plugs (408L and 408M) or oil cooler
2.
For the MTi and LTi models, remove the bearing frame foot-to-frame bolts (370F) and the frame foot
(241).
319
408N
408A
241
370F
408N
408W
372T
113A
408W
408M
761B
Figure 82: Plug removal
6.4.17 Guidelines for i-ALERT
®
2 Equipment Health Monitor disposal
Precautions
WARNING:
•
Explosive hazard and risk of personal injury. Heating to high temperatures could cause
combustion of the condition monitor. Never heat the condition monitor to temperatures in
excess of 149°C | 300°F or dispose of in a fire.
Guidelines
The battery contained in the condition monitor does not contain enough lithium to qualify as reactive haz-
ardous waste. Use these guidelines when disposing of the condition monitor.
•
The condition monitor is safe for disposal in the normal municipal waste stream.
•
Adhere to local laws when you dispose of the condition monitor.
6.4.18 Disassemble the C-face adapter
WARNING:
Risk of personal injury and equipment damage from dropping or tipping motor. The motor must
be properly supported with a clean, uncorroded eye bolt or a strap under both ends.
1.
Loosen the motor-mounting bolts and remove the motor.
6.4 Disassembly
98
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual