background image

Ver.2(2017.07) 

 

ルブリケーター

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contents 

 

Page    1 

   

 

・・・・・

  Important Notice for Safety 

Page    2 

  4 

・・・・・

  Notice Before Operation 

Page    5           

・・・・・

  Important Notices to use Air Motor 

Page    5           

・・・・・

  Specification Table 

Page    6           

・・・・・

  How To Use 

Page    7           

・・・・・

  In the below case happens, 

Page    7           

・・・・・

  Maintenance and Inspection 

Page    8 

   

 

・・・・・

  External Dimensions 

Page    9 

  10

・・・・・

  Guarantee and After-Sales Service 

 

 
Air-Motor Type Centrifugal Pump 
 

OPERATION MANUAL 

For

 

AMH1-25FC 

For

 

AMH1-25SUS 

Summary of Contents for AMH1-25FC

Page 1: ...Important Notices to use Air Motor Page 5 Specification Table Page 6 How To Use Page 7 In the below case happens Page 7 Maintenance and Inspection Page 8 External Dimensions Page 9 10 Guarantee and A...

Page 2: ...lways keep the manual at the operation site and you are advised to read the manual at any time you need DANGER WARNING ATTENTION This mark shows that imminence risk may cause the death accident or ser...

Page 3: ...care according to the manual or contact a doctor for professional advice Operate the product under open fire prohibited condition Ground wire before operating by all means The static electricity may c...

Page 4: ...ly new liquid If the liquids are mixed they may cause chemical reaction causing problem The site to be used Applicable liquid temperature 0 60 SHUT OFF Operation is absolutely not allowed SHUT OFF Ope...

Page 5: ...not suck slurry and or foreign materials Be sure to use the hose with dia of 3 8 In case the hose with shorter dia is used thepressure drops resulting in less function ability Do not operate under dr...

Page 6: ...g 1 Compressed air should be kept under 0 6 MPa Use pure compressed air without dust and or water etc 2 Be sure always to use air filter and lubricator so that the motor can keep normal rotation 3 Be...

Page 7: ...nd valves etc are connected be sure that they are firmly connected each other 2 Ground wire before operating by all means 3 Air plug should be gradually opened Control the discharging volume with air...

Page 8: ...e first If any consumable parts such as oil seal or packing etc are regularly and properly replaced P 7 Contact us for any assistance In case any unusual case or improper case on the pressure the disc...

Page 9: ...8 External Dimensions...

Page 10: ...9 Guarantee and After Sales Service...

Page 11: ...rantee period due to our defect designing defect assembling production However for the expenses and other losses related with mechanical troubles and or damage We takes neither responsibility nor comp...

Page 12: ...wrong handling or care not as instructed in the Manual Any problems due to repairing disassembling remodeling which were not done by us Any problems due to improper control and or improper care No ev...

Reviews: