6.6.14 Post-assembly checks
Perform these checks after you assemble the pump, then continue with pump startup:
•
Rotate the shaft by hand in order to make sure that it rotates easily and smoothly and that there is
no rubbing.
•
Open the isolation valves and check the pump for leaks.
6.6.15 Install the back pull-out assembly (except HT 3196)
WARNING:
Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting and
handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed shoes,
gloves, etc.) at all times. Seek assistance if necessary.
1.
Clean the casing fit and install the casing gasket (351) on the seal chamber and stuffing-box cover.
2.
Loosen the clamping bolts (370C) and jack bolts (370D) on the bearing housing.
423
370D
370C
Figure 139: Loosen clamp bolts and jack bolts on bearing housing
3.
Install the back pull-out assembly in the casing.
6.6 Reassembly
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
145