1
3
2
Item
Description
1.
Bolt Retainer, 2 required
2.
Shaft Guard Half, 2 required
3.
1.5/16-18 x .62 in. Hex Flange Screw, 2 required – shaft guard half to bearing frame
Figure 130: Required parts: STi
1.
Ensure that the mounting bolt for each shaft guard half is inserted with the bolt retainer in place for
captive hardware.
2.
Assemble a guard half from each side of the pump and fasten to the bearing frame.
3.
Ensure that adequate coverage is maintained for rotating components.
Figure 131: Shaft guard assembly
6.6.11.2 Install the shaft guard (MTi/LTi/XLTi/i17)
WARNING:
•
Running a pump without safety devices exposes operators to risk of serious personal in-
jury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
6.6 Reassembly
140
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual