INSTALLATION INSTRUCTIONS 

MODEL COND-1 

Condensate

 Pump

PREINSTALLATION CHECKLIST - ALL INSTALLATIONS

NOTICE TO INSTALLER:  Instructions must remain with installation.

1. 

  To help reduce the risk of electrical shock

, a properly 

grounded receptacle or control box of grounding type 

must be installed and protected by a ground fault circuit 

interrupter (GFCI) in accordance with the National Electrical 

Code and applicable local codes.  If pump is wired direct, a 

GFCI must be installed in the control box. 

(SEE WARNING 

BELOW)

2.

  

Make certain that the ground fault interrupter protected 

receptacle or control box is within reach of the

 

pump’s 

power supply cord. 

DO NOT USE AN EXTENSION CORD

Extension cords that are too long or too light do not deliver 

sufficient voltage to the pump motor. But more important, 

they could present a safety hazard if the insulation were to 

become damaged or the connection end were to fall into a 

damp or wet area. 

 3.

   Make sure the pump's electrical supply circuit is 

equipped with fuses or circuit breakers of proper 

1.    Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before 

using.

2.    Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting 

the installation. These materials should be retained for future reference.                   

1.    Check to be sure your power source is adequate to handle 

the amperage requirements of the motor as indicated on the 

pump or unit I.D. tag. 

 2.   All plumbing (discharge and drain lines) must be installed to 

meet local codes.   

                      

capacity.

 A separate branch circuit, sized according to the 

National Electrical Code for the current shown on the pump 

name plate is recommended.

4.

    TESTING FOR GROUND.

 As a safety measure, each 

electrical outlet should be checked for ground using an 

Underwriters Laboratory Listed circuit analyzer which will 

indicate if the power, neutral and ground wires are correctly 

connected to your outlet. If they are not, call a qualified 

licensed electrician.   

5.

  

Installation and checking of electrical circuits and hardware 

should only be performed by a qualified licensed electrician.

6.

    FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP 

FROM ITS POWER SOURCE BEFORE HANDLING.

7.

  

According to the state of California (Prop 65), this product 

contains chemicals known to the state of California to cause 

cancer and birth defects or other reproductive harm.

SEE BELOW FOR

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

NOTE: Pumps with the “UL” mark and pumps with the “US” mark 

are tested to UL Standard UL778. CSA Certified pumps are 

certified to CSA Standard C22.2 No. 108.

SEE BELOW FOR

LIST OF WARNINGS

visit our web site:

starwatersystems.com

SW1077 B

Summary of Contents for COND-1

Page 1: ...ng 2 Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting the installation These materials should be retained for future reference 1 Check to be sure your power source is adequate to handle the amperage requirements of the motor as indicated on the pump or unit I D tag 2 All plumbing discharge and drain lines must...

Page 2: ...R ANY CIRCUMSTANCES BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES SUCH AS BUT NOT LIMITED TO DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT LOSS OF PROFITS INCONVENIENCE OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE THE LIABILITY OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH LIABILITY IS BASED This warranty gives you specific legal...

Page 3: ...lling A Unit damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord with this condensate pump 5 DO NOT use a discharge pipe smaller than the pump discharge size 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and national codes and verify that the installation conforms to each of them ...

Page 4: ...ward slope to allow for gravity flow Note Local codes may require the use of a condensate neutralizer when using this pump Note Make sure the drain lines from the A C condenser are supported above the reservoir and no weight from the drain line is directed to the bottom of the reservoir SK1762 STEP 1 Mounting Location STEP 2 Installation of Condensate Drain Lines SK1762 CONDENSING GAS FURNACE OVER...

Page 5: ...he highest point possible Refer to Figure 3 1 3 2 From this point direct the discharge line to the location of the main drain maintain a continuous downward slope Note If a continuous downward slope is not possible then make an inverted U at the highest point of the discharge line Note Make sure the 3 8 ID tube is supported in a way it will not Kink or Pinch off blocking flow Figure 3 1 SK1764 STE...

Page 6: ...on Highest point of discharge line is less than 5 Check Valve is too tight or too loose O ring damaged Plug in Have a qualified electrician check fuse circuit Be certain the appliance is generating condensate Check drain line s and or discharge line for blockage Contact Factory Check drain line s and or discharge line for blockage Refer to Maintenance Guidelines section for cleaning instructions R...

Page 7: ...7 Copyright 2018 Star Water Systems All rights reserved NOTES ...

Page 8: ......

Reviews: