INSTALLATION INSTRUCTIONS
MODEL COND-1
Condensate
Pump
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
NOTICE TO INSTALLER: Instructions must remain with installation.
1.
To help reduce the risk of electrical shock
, a properly
grounded receptacle or control box of grounding type
must be installed and protected by a ground fault circuit
interrupter (GFCI) in accordance with the National Electrical
Code and applicable local codes. If pump is wired direct, a
GFCI must be installed in the control box.
(SEE WARNING
BELOW)
2.
Make certain that the ground fault interrupter protected
receptacle or control box is within reach of the
pump’s
power supply cord.
DO NOT USE AN EXTENSION CORD
.
Extension cords that are too long or too light do not deliver
sufficient voltage to the pump motor. But more important,
they could present a safety hazard if the insulation were to
become damaged or the connection end were to fall into a
damp or wet area.
3.
Make sure the pump's electrical supply circuit is
equipped with fuses or circuit breakers of proper
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before
using.
2. Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting
the installation. These materials should be retained for future reference.
1. Check to be sure your power source is adequate to handle
the amperage requirements of the motor as indicated on the
pump or unit I.D. tag.
2. All plumbing (discharge and drain lines) must be installed to
meet local codes.
capacity.
A separate branch circuit, sized according to the
National Electrical Code for the current shown on the pump
name plate is recommended.
4.
TESTING FOR GROUND.
As a safety measure, each
electrical outlet should be checked for ground using an
Underwriters Laboratory Listed circuit analyzer which will
indicate if the power, neutral and ground wires are correctly
connected to your outlet. If they are not, call a qualified
licensed electrician.
5.
Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
6.
FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
7.
According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
SEE BELOW FOR
LIST OF CAUTIONS
REFER TO WARRANTY ON PAGE 2.
NOTE: Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certified pumps are
certified to CSA Standard C22.2 No. 108.
SEE BELOW FOR
LIST OF WARNINGS