background image

W h e r e   I n n o v a t i o n   F l o w s

S Series

Twin Screw Pumps

www.maag.com

IOM

Installation

Operation

Maintenance

Manual

MAAG–14000-E-02EMEA

REPLACES MAAG-14000-E-02 

MAAG-14000-E

Summary of Contents for S Series

Page 1: ...W h e r e I n n o v a t i o n F l o w s S Series Twin Screw Pumps www maag com IOM Installation Operation Maintenance Manual MAAG 14000 E 02EMEA REPLACES MAAG 14000 E 02 MAAG 14000 E...

Page 2: ...ATION 3 SECTION 3 INSTALLATION 4 LOCATION 4 FOUNDATION 4 PIPING SYSTEM 5 PIPING SYSTEM ACCESSORIES 5 COUPLING ALIGNMENT 5 DOWELING 6 LUBRICATION 6 LUBRICATING GREASE 6 SECTION 4 OPERATION 7 PUMP PREPA...

Page 3: ...the idler shaft and to prevent metal contact between the meshed rotating screws thereby increasing the life expectancy of both the screws and shafts SAFETY PRECAUTIONS This manual contains basic refer...

Page 4: ...installed on suction and discharge lines near the pump NOTE A pipe safety valve is required in the discharge pipe of the pump PRODUCT WARRANTY Our warranty for shortcomings in the supply is laid down...

Page 5: ...attach lifting hooks to places marked on packing Strictly observe applicable safety regulations for lifting heavy loads NOTE Do not lift pump by bearing housing STEP 2 When lifting the pump attach li...

Page 6: ...ble to absorb vibration and provide rigid support for the entire pump unit Generally rein forced concrete is used as a foundation material The required area of the pump location and the location of an...

Page 7: ...hould be constructed of 40 meshes and 20 or 10 meshes for high viscosity applications The net screen area should be approximately 5 to 8 times the flow cross sectional area of the suction pipe However...

Page 8: ...nal feet LUBRICATION For all Maag Twin Screw Pumps lubricating oil and or lubricating grease are used for lubricating the bearings and gears of the pump see Figure 5 LUBRICATING OIL Gear oil in the ge...

Page 9: ...If any rubbing or binding occurs the cause must be located and corrected before starting the pump STEP 7 Check that motor rotation is correct refer to the rotation directional mark located on the pump...

Page 10: ...screws screw and casing are enlarged causing wear and tear Replace worn parts Large foreign matter or impurities among moving parts Counter rotate pump shafts remove foreign matter or impurities If n...

Page 11: ...tions regarding the maintenance of these accessories please refer to Manufacturer s Special Instructions in the Appendix WEEKLY MAINTENANCE STEP 1 If pump is not in use for one week open suction and d...

Page 12: ...S E C T I O N X NOTES...

Page 13: ...S E C T I O N X NOTES...

Page 14: ...S E C T I O N X NOTES...

Page 15: ...ty period Maag must be notified in writing within the warranty period of such defects and shall have the option of requiring return of parts or product to its factory for verification of any claim The...

Page 16: ...S fluiddynamics1 com GRISWOLD CENTRIFUGAL PUMPS griswoldpump com MAAG FILTRATION PLASTIC MANUFACTURING PROCESSING FILTRATION maag com MAAG INDUSTRIAL PUMPS GEAR SCREW PUMPS maag com MAAG PUMP SYSTEMS...

Reviews: