Goodrive350 series high-performance multifunction VFD
Basic operation guidelines
-91-
Setting
Function
Description
4
Output current (relative to
VFD)
0
–Twice the VFD rated current
5
Output current (relative to
motor)
0
–Twice the motor rated current
6
Output voltage
0
–1.5 times the VFD rated voltage
7
Output power
0
–Twice the motor rated power
8
Set torque value (bipolar)
0
–Twice the motor rated current. A negative value
corresponds to 0.0% by default.
9
Output torque (absolute
value)
0
– +/-(Twice the motor rated torque)
10
AI1 input value
0
–10V/0–20mA
11
AI2 input value
0V
–10V. A negative value corresponds to 0.0% by
default.
12
AI3 input value
0
–10V/0–20mA
13
High-speed pulse HDIA input 0.00
–50.00kHz
14
Value 1 set through
Modbus/Modbus TCP
communication
0
–1000
15
Value 2 set through
Modbus/Modbus TCP
communication
0
–1000
16
Value 1 set through
PROFIBUS/CANopen/Device
Net communication
0
–1000
17
Value 2 set through
PROFIBUS/CANopen/Device
Net communication
0
–1000
18
Value 1 set through Ethernet
communication
0
–1000
19
Value 2 set through Ethernet
communication
0
–1000
20
High-speed pulse HDIB input 0.00
–50.00kHz
21
Value 1 set through
EtherCAT/PROFINET/
EtherNET IP communication
0
–1000. A negative value corresponds to 0.0% by
default.
22
Torque current (bipolar)
0
–Triple the motor rated current. A negative value
corresponds to 0.0% by default.
23
Exciting current
0
–Triple the motor rated current. A negative value