![INVT GD350-004G-4 Operation Manual Download Page 278](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703278.webp)
Goodrive350 series high-performance multifunction VFD
Function parameter list
-269-
Function
code
Name
Description
Default Modify
P90.01
Winding/
unwinding mode
0: Winding
1: Unwinding
Note:
The motor forward rotation direction is the
winding direction. When using the tension control
mode, check whether the motor rotation direction
is correct in the winding mode; if not, change the
rotation direction by swapping two phase wires of
the motor. After the rotation direction is corrected,
the winding mode can be switched to the
unwinding mode by setting P90.01 to 1 or
changing the winding/unwiding switchover
terminals.
0
○
P90.02
Reel mechanical
transmission rate
0.01
–600.00
=Motor rotation speed/Reel rotation speed=Reel
diameter/Motor shaft diameter
1.00
○
P90.03
Max. linear
speed
0.0
–6000.0 m/min
1000.0
m/min
○
P90.04
Input source of
linear speed
0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI
5: Main traction encoder frequency-division input
0
◎
P90.05
Linear speed set
through keypad
0.0
–100.0%
20.0%
○
P90.06
Diameter of main
traction
0.0
–6000.0mm
99.0mm
○
P90.07
Main traction
drive ratio
0.000
–60.000
1.000
○
P90.08
Linear speed
ACC time
0.00
–600.00s
0.00s
○
P90.09
Linear speed
DEC time
0.00
–600.00s
0.00s
○
P90.10
Tension setting
0x00
–0x14
Ones place: Tension setting source
0: Keypad
1: AI1
2: AI2
3: AI3
0x00
◎