![INVT GD350-004G-4 Operation Manual Download Page 158](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703158.webp)
Goodrive350 series high-performance multifunction VFD
Function parameter list
-149-
Function
code
Name
Description
Default
value
Modify
motor 1
P02.16
Rated frequency
of synchronous
motor 1
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
◎
P02.17
Number of pole
pairs of
synchronous
motor 1
1
–128
2
◎
P02.18
Rated voltage of
synchronous
motor 1
0
–1200V
Depends
on model
◎
P02.19
Rated current of
synchronous
motor 1
0.8
–6000.0A
Depends
on model
◎
P02.20
Stator resistance
of synchronous
motor 1
0.001
–65.535Ω
Depends
on model
○
P02.21
Direct-axis
inductance of
synchronous
motor 1
0.01
–655.35mH
Depends
on model
○
P02.22
Quadrature-axis
inductance of
synchronous
motor 1
0.01
–655.35mH
Depends
on model
○
P02.23
Counter-emf
constant of
synchronous
motor 1
0
–10000
300
○
P02.24
Reserved
/
/
/
P02.25
Reserved
/
/
/
P02.26
Overload
protection of
motor 1
0: No protection
1: Common motor (with low-speed compensation).
As the cooling effect of common motor will be
degraded in low speed, the corresponding
electronic thermal protection value should also be
adjusted properly, the low compensation here
means to lower the overload protection threshold
2
◎