![INVT GD350-004G-4 Operation Manual Download Page 257](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703257.webp)
Goodrive350 series high-performance multifunction VFD
Function parameter list
-248-
Function
code
Name
Description
Default
value
Modify
1: Search the reference point every time
Bit3: Enable reference point calibration
0: Disable
1: Enable
Bit4: Positioning mode selection 1
0: Set direction positioning
1: Near-by direction positioning
Bit5: Positioning mode selection 2
0: Forward positioning
1: Reverse positioning
Bit6: Zeroing command selection
0: Electric level mode
1: Pulse mode
Bit7: Reference point calibration mode
0: Calibrate at the first time
1: Calibrate in real time
Bit8: Action selection after zeroing signal
cancellation (electric level type)
0: Switch to speed mode
1: Position lock mode
Bit9: Positioning completion signal selection
0: Electric level signal
1: Pulse signal
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bits 11
–15: Reserved
P22.01
Speed of spindle
orientation
During spindle orientation, the speed of the
position point of orientation will be searched, and
then it will switch over to position control
orientation.
Setting range: 0.00
–100.00Hz
10.00Hz
○
P22.02
Deceleration time
of spindle
orientation
Deceleration time of spindle orientation.
Spindle orientation deceleration time means the
time needed for the VFD to decelerate from Max.
output frequency (P00.03) to 0Hz.
Setting range: 0.0
–100.0s
3.0s
○
P22.03
Spindle zeroing
position 0
You can select the zeroing positions of four
spindles by terminals (functions 46 and 47).
0
○