Goodrive350 series high-performance multifunction VFD
Function parameter list
-180-
Function
code
Name
Description
Default
value
Modify
protection.
00000: Clear the previous user password and
disable password protection.
After the user password is set and takes effect,
you cannot enter the parameter menu if you enter
an incorrect password. Please remember your
password and save it in a secure place.
After you exit the function code editing interface,
the password protection function is enabled within
1 minute. If password protection is enabled,
"
0.0.0.0.0
" is displayed when you press the
PRG/ESC key again to enter the function code
editing interface. You need to enter the correct
user password to enter the interface.
Note:
Restoring the default values may delete the
user password. Exercise caution when using this
function.
P07.01 Reserved
/
/
/
P07.02 Function of keys
Range: 0x00
–0x27
Ones: Function selection of QUICK/JOG key
0: No function
1: Jogging
2: Reserved
3: Forward/reverse rotation switchover
4: Clear UP/DOWN setting
5: Coast to stop
6: Switch over the running command reference
mode in sequence
7: Reserved
Tens: Reserved
0x01
◎
P07.03
Running
command
channel
switchover
sequence of
QUICK key
When P07.02=6, set the switchover sequence of
running command channel.
0: keypad control
→terminal control→
communication control
1: keypad control
←→terminal control
2: keypad control
←→communication control
3: terminal control
←→communication control
0
○
P07.04
Stop function
selection of
Validness selection of stop function of STOP/RST.
For fault reset, STOP/RST is valid under any
0
○