Goodrive350 series high-performance multifunction VFD
Function parameter list
-232-
Function
code
Name
Description
Default
value
Modify
P17.54
Actual PID
proportional gain
0.00
–100.00
0.00
●
P17.55
Actual PID
integral time
0.00
–10.00s
0.00s
●
P17.56
Actual PID
differential time
0.00
–10.00s
0.00s
●
P17.57
Peak value at
100Hz frequency
component
(square-wave
orthogonal
function
detected)
0.0
–300.0V
Peak value of bus voltage fluctuation at 100Hz
frequency component, which is detected by using
a square-wave orthogonal function
0.0V
●
P17.58
Peak value at
100Hz frequency
component
(sine-wave
orthogonal
function
detected)
0.0
–300.0V
Peak value of bus voltage fluctuation at 100Hz
frequency component, which is detected by using
a sine-wave orthogonal function
0.0V
●
P17.59
–
P17.63
Reserved
0
–65535
0
●
P18
––
Closed-loop control state check
Function
code
Name
Description
Default
value
Modify
P18.00
Actual frequency
of encoder
The actual-measured encoder frequency; the
value of forward running is positive; the value of
reverse running is negative.
Range: -999.9
–3276.7Hz
0.0Hz
●
P18.01
Encoder position
count value
Encoder count value, quadruple frequency,
Range: 0
–65535
0
●
P18.02
Encoder Z pulse
count value
Corresponding count value of encoder Z pulse.
Range: 0
–65535
0
●
P18.03
High bit of
position
reference value
High bit of position reference value, zero out after
stop.
Range: 0
–30000
0
●
P18.04
Low bit of
position
Low bit of position reference value, zero out after
stop.
0
●