Goodrive350 series high-performance multifunction VFD
Function parameter list
-169-
Function
code
Name
Description
Default
value
Modify
is positive.
When the bit is set to 1, the input terminal polarity
is negative.
0x000
–0x3F
P05.09
Digital filter time
Set the sampling filtering time of the S1
–S4, HDIA,
and HDIB terminals. In cases where interference is
strong, increase the value of this parameter to
avoid mal-operation.
0.000
–1.000s
0.010s
○
P05.10
Virtual terminal
setting
0x00
–0x3F (0: disable, 1: enable)
BIT0: S1 virtual terminal
BIT1: S2 virtual terminal
BIT2: S3 virtual terminal
BIT3: S4 virtual terminal
BIT4: HDIA virtual terminal
BIT5: HDIB virtual terminal
0x00
◎
P05.11
2/3 Wire control
mode
This parameter specifies the 2/3 Wire control
mode.
0: 2-Wire control 1; integrate enabling function with
direction. This mode is the most popular dual-line
mode. Direction of motor rotation is determined by
the defined FWD/REV terminal command.
FWD
REV
COM
K1
K2
Running
command
FWD
REV
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Stop
Hold
Forward
running
Reverse
running
1: 2-wire control 2; separate enabling function with
direction. In this mode, the defined FWD is
enabling terminal, and the direction is determined
by the state of REV.
0
◎