Goodrive350 series high-performance multifunction VFD
Basic operation guidelines
-106-
Set
value
Function
Description
undervoltage threshold of the inverter
27
Z pulse output
Output is valid when the encoder Z pulse is
arrived, and is invalid after 10 ms.
28
During pulse superposition
Output is valid when the pulse superposition
terminal input function is valid
29
STO action
Output when STO fault occurred
30
Positioning completed
Output is valid when position control positioning is
completed
31
Spindle zeroing completed
Output is valid when spindle zeroing is completed
32
Spindle scale-division completed Output is valid when spindle scale-division is
completed
33
In speed limit
Output is valid when the frequency is limited
34
Virtual terminal output of
EtherCAT/PROFINET/
EtherNet IP communication
The corresponding signal is output according to
the set value of PROFINET communication. When
it is set to 1, the ON signal is output, and when it is
set to 0, the OFF signal is output.
35
Reserved
/
36
Speed/position control switchover
completed
Output is valid when the mode switchover is
completed
37
Any frequency reached
The frequency reached signal is output when the
present ramp reference frequency is greater than
the detection value for frequency being reached.
38
–40
Reserved
/
41
Y1
Y1 from the programmable card
42
Y2
Y2 from the programmable card
43
HDO
HDO from the programmable card
44
RO1
RO1 from the programmable card
45
RO2
RO2 from the programmable card
46
RO3
RO3 from the programmable card
47
RO4
RO4 from the programmable card
48
EC PT100 detected OH pre-alarm
Pre-alarm of overheating (OH) detected by the
expansion card (EC) with PT100.
49
EC PT1000 detected OH
pre-alarm
Pre-alarm of OH detected by the EC with PT1000.
50
AI/AO detected OH pre-alarm
Pre-alarm of OH detected by AI/AO.
51
Stopped or running at zero speed
The VFD is in stopped state or running at zero
speed.
52
Disconnection detected in tension Disconnection is detected when the disconnection