5. Quick Setup
- 98 -
5
CONTINUE
Para.
Parameter name
Default
Commission
if an analog output is
used
F5-01
FM (switch signal) function selection
0
34: Zero current status
35: IGBT temperature reached
36:Software current limit exceeded
37: Frequency lower limit reached (having output at stop)
38: Alarm output
39: Motor overheat warning
40: Current running time reached
41: Fault output (no output at undervoltage)
F5-02
Relay function selection(T/A-T/B-T/C)
2
Setting range same as FM;
F5-03
Relay function selection (P/A-P/B-P/C)
0
Setting range same as FM; the relay P/A-P/B-P/C is
on extension I/O card.
F5-04
DO1 function selection
1
Setting range same as FM
F5-05
Extension card DO2 function selection
4
Setting range same as FM
F5-06
FM (pulse signal) function selection
0
0: Running frequency
1: Set frequency
2: Output current
3: Reserved
4: Output power
5: Output voltage
6: Pulse input
7: AI1
8: AI2
9: AI3
10: Length
11: Count value
12: Communication setting
13: Motor rotational speed
14: Output current
15: Output voltage
16: Reserved
Set AO function
F5-07
AO1 function selection
0
Setting range same as F5-06
F5-08
AO2 function selection
1
Setting range same as F5-06; AO2 is on extension card.
CONTINUE
Para.
Parameter name
Default
Commission
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......
Page 350: ......