7. Interfaces and Communication
- 222 -
7
Ƶ
Stop/RUN Parameters
Parameter
Address
Description
Parameter
Address
Description
1000
Communication setting value
(Decimal): -10000 to 10000
1010
PID reference
1001
Running frequency
1011
PID feedback
1002
Bus voltage
1012
PLC process
1003
Output voltage
1013
Pulse input frequency, unit: 0.01
kHz
1004
Output current
1014
Feedback speed, unit 0.1Hz
1005
Output power
1015
Remaining running time
1006
Output torque
1016
AI1 voltage before correction
1007
Running speed
1017
AI2 voltage before correction
1008
DI input indication
1018
AI3 voltage before correction
1009
DO output indication
1019
Linear speed
100A
AI1 voltage
101A
Current power-on time
100B
AI2 voltage
101B
Current running time
100C
AI3 voltage
101C
Pulse input frequency, unit 1Hz
100D
Counting value input
101D
Communication reference
100E
Length value input
101E
Actual feedback speed
100F
Load speed
101F
Main frequency reference display
-
-
1020
Auxiliary frequency reference
display
Note
Ɣ
Communication setting value indicates percentage: 10000
corresponds to 100.00%, and -10000 corresponds to -100.00%.
Ɣ
With regard to frequency, communication reference is a
percentage of F0-10 (maximum frequency).
Control command input to AC drive (write-only):
Command Word Address
Command Word Function
2000H
0001: Forward run
0002: Reverse run
0003: Forward jog
0004: Reverse jog
0005: Coast to stop
0006: Decelerate to stop
0007: Fault reset
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......
Page 350: ......