10. Troubleshooting
- 279 -
11
Operating Panel Display
Fault Name
Communication fault
Cause
Possible Solution
Host computer is in abnormal state.
Check the cable of host computer.
Communication cable is abnormal.
Check the communication cables.
The serial port communication
protocol (F0-28) of extension
communication card is set
improperly.
Set F0-28 of extension communication card correctly.
Communication parameters in group
Fd are set improperly.
Set communication parameters in group Fd properly.
After all the preceding checkings are done but the fault still exists, restore the default settings.
Operating Panel Display
Fault Name
Contactor fault
Cause
Possible Solution
Drive board and power supply are
abnormal.
Replace drive board or power supply board.
Contactor is abnormal.
Replace contactor.
The lightning protection board is
abnormal.
Replace the lightning protection board.
Operating Panel Display
Fault Name
Current detection fault
Cause
Possible Solution
The hall is abnormal.
Replace the hall .
The drive board is abnormal.
Replace the drive board.
Operating Panel Display
Fault Name
Motor auto-tuning fault
Cause
Possible Solution
Motor parameters are not set
according to nameplate.
Set motor parameters correctly according to nameplate.
Motor auto-tuning times out.
Check the cable connecting AC drive and motor.
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......
Page 350: ......