5. Quick Setup
- 96 -
5
CONTINUE
Para.
Parameter name
Default
Commission
F4-00
DI1 function selection
1
33: External fault normally closed (NC) input
)UHTXHQF\PRGL¿FDWLRQIRUELGGHQ
35: PID action direction reverse
36: External STOP terminal 1
37: Command source switchover terminal 2
38: PID integral disabled
39: Switchover between main frequency source X and preset
frequency
40: Switchover between auxiliary frequency source Y and preset
frequency
41: Motor selection terminal 1
42: Motor selection terminal 2
43: PID parameter switchover
8VHUGH¿QHGIDXOW
8VHUGH¿QHGIDXOW
46: Speed control/Torque control switchover
47: Emergency stop
48: External STOP terminal 2
49: Deceleration DC injection braking
50: Clear the current running time
51–59: Reserved
Setting range:0 to 59;
F4-01
DI2 function selection
4
Setting range same as DI1.
F4-02
DI3 function selection
9
Setting range same as DI1.
F4-03
DI4 function selection
12
Setting range same as DI1.
F4-04
DI5 function selection
13
Setting range same as DI1;
F4-05
DI6 function selection
0
Setting range same as DI1;
F4-06
DI7 function selection
0
Setting range same as DI1;
F4-07
DI8 function selection
0
Setting range same as DI1
F4-08
DI9 function selection
0
Setting range same as DI1.
F4-09
DI10 function selection
0
Setting range same as DI1;
CONTINUE
Para.
Parameter name
Default
Commission
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......
Page 350: ......