Read AC drive state (read-only):
Command Word Address
Command Word Function
3000H
0001: Forward RUN
0002: Reverse RUN
0003: Stop
Parameter lock password check
If "8888H" is returned, it indicates that password check is passed.
Password Address
Password Content
1F00H
*****
DO terminal control (write-only)
Command Address
Command Content
2001H
BIT0: DO1 control
BIT1: DO2 control
BIT2: RELAY1 control
BIT3: RELAY2 control
BIT4: FMR control
BIT5: VDO1
BIT6: VDO2
BIT7: VDO3
BIT8: VDO4
BIT9: VDO5
AO1 control (write-only)
Command Address
Command Content
2002H
0 to 7FFF indicates 0% to 100%.
AO2 control (write-only)
Command Address
Command Content
2003H
0 to 7FFF indicates 0% to 100%.
Pulse output control (write-only)
Command Address
Command Content
2004H
0 to 7FFF indicates 0% to 100%.