5. Quick Setup
- 95 -
5
CONTINUE
Para.
Parameter name
Default
Commission
If any digital input is used
Set DI function
F4-00
DI1 function selection
1
0: No function
1: Forward RUN (FWD)
2: Reverse RUN (REV)
3: Three-wire control
4: Forward JOG (FJOG)
5: Reverse JOG (RJOG)
6: Terminal UP
7: Terminal DOWN
8: Coast to stop
9: Fault reset (RESET)
10: RUN pause
11: External fault normally open (NO) input
12: Multi-reference terminal 1
13: Multi-reference terminal 2
14: Multi-reference terminal 3
15: Multi-reference terminal 4
16: Terminal 1 for acceleration/deceleration time selection
17: Terminal 2 for acceleration/deceleration time selection
18: Frequency source switchover
19: UP and DOWN setting clear (terminal, keypad)
20: Command source switchover terminal 1
21: Acceleration/Deceleration prohibited
22: PID pause
23: PLC status reset
24: Swing pause
25: Counter input
26: Counter reset
27: Length count input
28: Length reset
29: Torque control prohibited
30: Pulse input (enabled only for DI5)
31: Reserved
32: Immediate DC injection braking
CONTINUE