8. Peripherals and Options
- 255 -
8
Ɣ
DIP switch setting
3UR¿EXV'3&RPPXQLFDWLRQ6ODYH$GGUHVV6HWWLQJ
Slave
Address
DIP Switch
1
2
3
4
5
6
7
8
Keep the
OFF state
(OFF:
MD38DP2).
0
0
0
0
0
0
0
Reserved
ON
1
2
3
4
5
6
7
8
S1
Reserved
DP slave
address setting
1 2 3 4 5 6 7 8
0
0
0
0
0
0
1
1
0
0
0
0
0
1
0
2
0
0
0
0
1
1
3
...
…
1
1
1
1
1
0
1
123
1
1
1
1
1
1
0
124
1
1
1
1
1
1
1
125
Ɣ
Indicators
Indicator
Indication
State Description
D4 in red
Power supply
indicator
ON
The drive is powered on.
OFF
The drive is not powered on or DP card is installed
improperly.
D3 in yellow DP card
and master
communication
indicator
ON
Communication between DP card and the master
is normal.
OFF
There is no communication between DP card and
the master (check PROFIBUS cable connection
and setting of station No.).
Flash The master does not operate or error occurs on
communication between DP card and the master .
D2 in green DP card
and drive
communication
indicator
ON
Communication between DP card and the drive is
normal.
OFF
Communication between DP card and the drive
fails (check the baud rate setting).
Flash Interference exists on communication between DP
card and the drive or extension card address is
not within the rang of 1 to 125.
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......
Page 350: ......