![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 44](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775044.webp)
Secondary
I/O
Drawer
Operator
Panel
Message
Hierarchy
The
messages
that
are
displayed
in
the
operator
panel
on
secondary
I/O
drawers
are
arranged
hierarchically,
from
highest
priority
to
lowest
priority.
The
message
hierarchy
is
as
follows:
1.
8-character
error
code
This
indicates
a
critical
error;
the
drawer
power
will
be
shut
down.
Standby
power
is
still
on,
so
the
error
message
is
still
displayed
in
the
operator
panel.
The
I/O
drawer
Attention
LED
will
be
on.
The
error
code
displays
on
the
top
line
of
the
display
panel,
left-justified.
A
FRU
part
number
may
also
be
displayed,
right-justified,
in
the
second
line
of
the
display.
2.
8-character
informational
message
This
is
a
noncritical
message,
so
the
drawer
power
will
not
be
shut
down.
The
message
should
be
investigated
to
see
if
service
actions
are
indicated.
A
FRU
part
number
may
also
be
displayed,
right-justified,
in
the
second
line
of
the
display.
When
8-character
codes
are
displayed,
they
are
in
the
form
10n1xxxx,
where
n
is
the
drawer
number.
3.
8-character
checkpoint
There
is
one
8-character
checkpoint
that
displays,
10n100AA,
where
n
is
the
drawer
number.
This
checkpoint
indicates
that
the
system
power
control
network
firmware
is
being
updated,
and
the
checkpoint
displays
for
approximately
15
seconds.
This
is
the
only
checkpoint
that
displays
on
a
secondary
I/O
drawer
operator
panel.
4.
Drawer
number
This
will
be
in
the
form
U0.n,
where
n
is
the
drawer
number.
This
message
will
normally
display
unless
a
higher-level
message
is
required.
When
ac
power
(dc
power
in
a
dc-powered
system)
has
been
disconnected
from
the
system,
then
reconnected,
the
I/O
drawer
addresses
on
the
secondary
drawers
will
temporarily
appear
in
the
format
*0n,
where
n
is
the
drawer
number.
After
the
system
is
powered
on,
and
the
boot
sequence
has
been
initiated,
the
drawer
numbers
are
restored
to
the
U0.n
format.
26
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......