Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406A
023E
Self
test
detected
memory
DIMM
group
fault
Memory
quad
D
odd,
riser
1
Location:
U1.1-P1-M1.7
x4
406A
023F
Self
test
detected
memory
DIMM
group
fault
Memory
quad
D
even,
riser
1
Location:
U1.1-P1-M1.8
x4
406A
02FF
Self
test
detected
memory
on
riser
fault
All
memory
on
riser
1
Location:
U1.1-P1-M1.1
x32
Memory
failure
on
riser
card
1
that
cannot
be
automatically
isolated.
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
and
run
CEC
drawer
minimum
configuration
for
further
isolation.
406A
0300
Self
test
detected
processor
card
fault
Processor
card
Location:
U1.1-P1-C1
406A
0400
Self
test
detected
processor
card
fault
Processor
card
Location:
U1.1-P1-C2
406A
0500
Self
test
detected
memory
riser
card
fault
Memory
riser
card
2
Location:
U1.1-P1-M1
406A
0501
Self
test
detected
memory
DIMM
fault
Memory
DIMM
1,
riser
2
Location:
U1.1-P1-M2.1
406A
0502
Self
test
detected
memory
DIMM
fault
Memory
DIMM
2,
riser
2
Location:
U1.1-P1-M2.2
406A
0503
Self
test
detected
memory
DIMM
fault
Memory
DIMM
9,
riser
2
Location:
U1.1-P1-M2.9
406A
0504
Self
test
detected
memory
DIMM
fault
Memory
DIMM
10,
riser
2
Location:
U1.1-P1-M2.10
406A
0505
Self
test
detected
memory
DIMM
fault
Memory
DIMM
17,
riser
2
Location:
U1.1-P1-M2.17
406A
0506
Self
test
detected
memory
DIMM
fault
Memory
DIMM
18,
riser
2
Location:
U1.1-P1-M2.18
406A
0507
Self
test
detected
memory
DIMM
fault
Memory
DIMM
25,
riser
2
Location:
U1.1-P1-M2.25
406A
0508
Self
test
detected
memory
DIMM
fault
Memory
DIMM
26,
riser
2
Location:
U1.1-P1-M2.26
406A
050D
Self
test
detected
memory
DIMM
group
fault
Memory
octal
A,
riser
2
Location:
U1.1-P1-M2.1
x8
406A
050E
Self
test
detected
memory
DIMM
group
pair
A
fault
Memory
quad
A
odd,
riser
2
Location:
U1.1-P1-M2.1
x4
406A
050F
Self
test
detected
memory
DIMM
group
fault
Memory
quad
A
even,
riser
2
Location:
U1.1-P1-M2.2
x4
406A
0511
Self
test
detected
memory
DIMM
fault
Memory
DIMM
3,
riser
2
Location:
U1.1-P1-M2.3
406A
0512
Self
test
detected
memory
DIMM
fault
Memory
DIMM
4,
riser
2
Location:
U1.1-P1-M2.4
406A
0513
Self
test
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
2
Location:
U1.1-P1-M2.11
406A
0514
Self
test
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
2
Location:
U1.1-P1-M2.12
238
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......