Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406F
00B3
Error
code
generation/logging
detected
clock
fault
1.
Clock
card
Location:
U1.1-P1.1.1
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
406F
00B7
Error
code
generation/logging
detected
insufficient
hardware
resources
to
continue
IPL
This
error
code
appears
after
the
initial
testing
by
the
service
processor
firmware
on
the
CEC
was
completed
correctly,
but
a
problem
occurred
when
the
firmware
tried
to
communicate
outside
the
CEC.
Suspect
a
problem
with
the
RIO
interface,
either
cables
or
adapters.
406F
0200
Error
code
generation/logging
detected
memory
riser
card
fault
Memory
riser
card
1
Location:
U1.1-P1-M1
406F
0201
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
1,
riser
1
Location:
U1.1-P1-M1.1
406F
0202
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
2,
riser
1
Location:
U1.1-P1-M1.2
406F
0203
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
9,
riser
1
Location:
U1.1-P1-M1.9
406F
0204
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
10,
riser
1
Location:
U1.1-P1-M1.10
406F
0205
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
17,
riser
1
Location:
U1.1-P1-M1.17
406F
0206
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
18,
riser
1
Location:
U1.1-P1-M1.18
406F
0207
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
25,
riser
1
Location:
U1.1-P1-M1.25
406F
0208
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
26,
riser
1
Location:
U1.1-P1-M1.26
406F
020D
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
octal
A,
riser
1
Location:
U1.1-P1-M1.1
x8
406F
020E
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
quad
A
odd,
riser
1
Locations:
U1.1-P1-M1.1
x4
406F
020F
Error
code
generation/logging
detected
memory
DIMM
group
fault
Memory
quad
A
even,
riser
1
Locations:
U1.1-P1-M1.2
x4
406F
0211
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
3,
riser
1
Location:
U1.1-P1-M1.3
406F
0212
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
4,
riser
1
Location:
U1.1-P1-M1.4
406F
0213
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
1
Location:
U1.1-P1-M1.11
406F
0214
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
1
Location:
U1.1-P1-M1.12
406F
0215
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
19,
riser
1
Location:
U1.1-P1-M1.19
406F
0216
Error
code
generation/logging
detected
memory
DIMM
fault
Memory
DIMM
20,
riser
1
Location:
U1.1-P1-M1.20
268
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......