![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 172](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775172.webp)
Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E604
SSA
PCI
adapter
BIST
and
subsequent
POSTs
have
completed
successfully.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E605
SSA
PCI
adapter
BIST
has
completed
successfully
but
the
subsequent
POSTs
have
failed.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E60E
SSA
PCI
adapter
open
firmware
about
to
exit
(no
stack
corruption).
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E60F
SSA
PCI
adapter
open
firmware
has
run
unsuccessfully.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E6FF
SSA
PCI
adapter
open
firmware
about
to
exit
(with
stack
corruption).
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E700
Create
system
firmware
VPD
Replace
the
primary
I/O
drawer
backplane.
E701
Create
memory
VPD.
See
“Note”
on
page
137.
E702
Create
processor
card
VPD.
See
“Note”
on
page
137.
E703
Create
operator
panel
VPD.
See
“Note”
on
page
137.
E704
Create
CEC
VPD.
See
“Note”
on
page
137.
E705
Create
clock
card
VPD.
See
“Note”
on
page
137.
E706
Create
RIO
extender
card
VPD.
See
“Note”
on
page
137.
E707
Create
system
VPD.
See
“Note”
on
page
137.
E708
Create
RIO
to
PCI
adapter
VPD.
See
“Note”
on
page
137.
E709
Create
VPD
via
SPCN.
See
“Note”
on
page
137.
E70A
Create
service
processor
VPD.
See
“Note”
on
page
137.
E8xx
RTAS
initialization
problem.
Call
for
support.
EAA1
Probe
PCI-PCI
bridge.
Follow
the
repair
actions
for
checkpoint
E151.
Note:
If
you
receive
a
four-digit
code
in
the
range
of
E1xx
to
EFFF
that
is
not
listed
in
the
table
above,
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110.
154
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......