Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406C
3282
IPL
MOPS
detected
primary
RIO
port
1
fault
1.
Check
RIO
cable
Location:
U0.1-P1.1/Q2
2.
RIO
bus
adapter
Location:
U0.1-P1.1
406C
3283
IPL
MOPS
detected
primary
RIO
ports
fault
RIO
bus
adapter
Location:
U0.1-P1.1
406C
3284
IPL
MOPS
detected
PCI
controller
PHB0
1.
RIO
bus
adapter
Location:
U0.1-P1.1
2.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
406C
3285
IPL
MOPS
detected
PCI
controller
PHB1
1.
RIO
bus
adapter
Location:
U0.1-P1.1
2.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
406C
3286
IPL
MOPS
detected
PCI
controller
PHB2
1.
RIO
bus
adapter
Location:
U0.1-P1.1
2.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
406D
0001
Attention
handler
detected
CEC
backplane
failure
CEC
backplane
Location:
U1.1-P1
406D
0003
Attention
handler
detected
processor
fault
All
processors
Location:
U1.1-P1-C1
406D
0009
Attention
handler
detected
memory
fault
All
memory
Location:
U1.1-P1-M1
x2
406D
00A0
Attention
handler
detected
CSP
service
processor
firmware
fault
Update
system
firmware
Location:
U0.1-P1/Y1
406D
00A1
Attention
handler
detected
AIX
or
system
firmware
fault
1.
Check
for
AIX
updates
2.
Check
for
system
firmware
updates
Location:
U0.1-P1/Y1
406D
00A2
Attention
handler
detected
service
processor
firmware
(processor
runtime
diagnostics)
fault
Check
for
system
firmware
updates
Location:
U0.1-P1/Y1
406D
00A3
Attention
handler
detected
memory
plugging
fault
All
pluggable
memory
406D
00A4
Attention
handler
detected
application
caused
fault
Application
software
406D
00A5
Attention
handler
detected
invalid
system
configuration
Verify
system
components
are
supported
and
properly
installed.
406D
00A6
Attention
handler
detected
no
usable
memory
1.
Ensure
that
CEC
memory
is
properly
installed.
2.
If
more
than
one
DIMM
is
called
out,
go
to
the
service
processor
Memory
Configuration/Deconfiguration
Menu
to
verify
memory
DIMMs
state.
See
″
Memory
Configuration/Deconfiguration
Menu
″
on
page
374
for
more
information.
406D
00A7
Attention
handler
detected
hardware
problem
Go
to
minimum
configuration
and
also
run
CEC
minimum
configuration
406D
00B0
Attention
handler
detected
bus
controller
lock-unlock
failure
RIO
bus
adapter
Location:
U0.1-P1.1
254
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......