Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406E
0207
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
25,
riser
1
Location:
U1.1-P1-M1.25
406E
0208
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
26,
riser
1
Location:
U1.1-P1-M1.26
406E
020D
Scan
control
routines
detected
memory
DIMM
group
fault
Memory
octal
A,
riser
1
Location:
U1.1-P1-M1.1
x8
406E
020E
Scan
control
routines
detected
memory
DIMM
group
fault
Memory
quad
A
odd,
riser
1
Locations:
U1.1-P1-M1.1
x4
406E
020F
Scan
control
routines
detected
memory
DIMM
group
fault
Memory
quad
A
even,
riser
1
Locations:
U1.1-P1-M1.2
x4
406E
0211
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
3,
riser
1
Location:
U1.1-P1-M1.3
406E
0212
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
4,
riser
1
Location:
U1.1-P1-M1.4
406E
0213
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
1
Location:
U1.1-P1-M1.11
406E
0214
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
1
Location:
U1.1-P1-M1.12
406E
0215
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
19,
riser
1
Location:
U1.1-P1-M1.19
406E
0216
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
20,
riser
1
Location:
U1.1-P1-M1.20
406E
0217
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
27,
riser
1
Location:
U1.1-P1-M1.27
406E
0218
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
28,
riser
1
Location:
U1.1-P1-M1.28
406E
021D
Scan
control
routines
detected
memory
DIMM
group
fault
Memory
octal
B,
riser
1
Location:
U1.1-P1-M1.3
x8
406E
021E
Scan
control
routines
detected
memory
DIMM
group
pair
A
fault
Memory
quad
B
odd,
riser
1
Location:
U1.1-P1-M1.3
x4
406E
021F
Scan
control
routines
detected
memory
DIMM
group
fault
Memory
quad
B
even,
riser
1
Location:
U1.1-P1-M1.4
x4
406E
0221
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
5,
riser
1
Location:
U1.1-P1-M1.5
406E
0222
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
6,
riser
1
Location:
U1.1-P1-M1.6
406E
0223
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
13,
riser
1
Location:
U1.1-P1-M1.13
406E
0224
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
14,
riser
1
Location:
U1.1-P1-M1.14
406E
0225
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
21,
riser
1
Location:
U1.1-P1-M1.21
406E
0226
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
22,
riser
1
Location:
U1.1-P1-M1.22
406E
0227
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
29,
riser
1
Location:
U1.1-P1-M1.29
262
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......