![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 232](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775232.webp)
Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
4066
0534
Scan
interface
basic
assurance
tests
detected
memory
DIMM
fault
Memory
DIMM
16,
riser
2
Location:
U1.1-P1-M2.16
4066
0535
Scan
interface
basic
assurance
tests
detected
memory
DIMM
fault
Memory
DIMM
23,
riser
2
Location:
U1.1-P1-M2.23
4066
0536
Scan
interface
basic
assurance
tests
detected
memory
DIMM
fault
Memory
DIMM
24,
riser
2
Location:
U1.1-P1-M2.24
4066
0537
Scan
interface
basic
assurance
tests
detected
memory
DIMM
fault
Memory
DIMM
31,
riser
2
Location:
U1.1-P1-M2.31
4066
0538
Scan
interface
basic
assurance
tests
detected
memory
DIMM
fault
Memory
DIMM
32,
riser
2
Location:
U1.1-P1-M2.32
4066
053D
Scan
interface
basic
assurance
tests
detected
memory
DIMM
group
fault
Memory
octal
D,
riser
2
Location:
U1.1-P1-M2.7
x8
4066
053E
Scan
interface
basic
assurance
tests
detected
memory
DIMM
group
fault
Memory
quad
D
odd,
riser
2
Location:
U1.1-P1-M2.7
x4
4066
053F
Scan
interface
basic
assurance
tests
detected
memory
DIMM
group
fault
Memory
quad
D
even,
riser
2
Location:
U1.1-P1-M2.8
x4
4066
05FF
Scan
interface
basic
assurance
tests
detected
memory
on
riser
fault
Memory
failure
on
riser
card
2
that
cannot
be
automatically
isolated.
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
and
run
CEC
drawer
minimum
configuration
for
further
isolation.
4066
0600
Scan
interface
basic
assurance
tests
detected
CEC
RIO
bus
adapter
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
0601
Scan
interface
basic
assurance
tests
detected
clock
card
fault
CEC
clock
card
Location:
U1.1-P1.1.1
4066
3101
Scan
interface
basic
assurance
tests
detected
RIO
port
0
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
3102
Scan
interface
basic
assurance
tests
detected
RIO
port
1
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
3103
Scan
interface
basic
assurance
tests
detected
RIO
port
2
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
3104
Scan
interface
basic
assurance
tests
detected
RIO
port
3
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
3121
Scan
interface
basic
assurance
tests
detected
RIO
cable
on
port
0
fault
1.
RIO
cable
on
port
0
Location:
U1.1-P1.1/Q1
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
3122
Scan
interface
basic
assurance
tests
detected
RIO
cable
on
port
1
fault
1.
RIO
cable
on
port
1
Location:
U1.1-P1.1/Q2
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4066
3123
Scan
interface
basic
assurance
tests
detected
RIO
cable
on
port
2
fault
1.
RIO
cable
on
port
2
Location:
U1.1-P1.1/Q3
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
214
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......