Table
6.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
2201
1001
PCI
token
ring
adapter
Adapter
failed
to
complete
hardware
initialization.
Replace
the
Adapter
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
25A0
0001
Cache
L2
controller
failure
1.
Replace
the
processor
card.
See
“Determining
Location
Code”
on
page
160
for
processor
card
location
information.
2.
Replace
the
CEC
backplane.
Location:
U1.1-P1.
25A1
0001
Cache
L2
SRAM
failure
1.
Replace
the
processor
card.
See
“Determining
Location
Code”
on
page
160
for
processor
card
location
information.
25A8
0xxx
NVRAM
problems
Errors
reported
against
NVRAM
can
be
caused
by
low
battery
voltage
and
(more
rarely)
power
outages
that
occur
during
normal
system
usage.
With
the
exception
of
the
25A80000
error,
these
errors
are
warnings
that
the
NVRAM
data
content
had
to
be
reestablished
and
do
not
require
any
FRU
replacement
unless
the
error
is
persistent.
When
one
of
these
errors
occurs,
any
system
customization
(for
example,
boot
device
list)
information
has
been
lost,
the
system
may
need
to
be
reconfigured.
If
the
error
is
persistent,
replace
primary
I/O
drawer
backplane
Location:
U0.1-P1
25A8
0000
Initialization
failed,
device
test
failed
Refer
to
Action
under
error
code
25A80xxx.
25A8
0001
Init-NVRAM
invoked,
all
of
NVRAM
initialized
Refer
to
Action
under
error
code
25A80xxx.
25A8
0002
Init-NVRAM
invoked,
some
data
partitions
may
have
been
preserved.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0011
Data
corruption
detected,
all
of
NVRAM
initialized
Refer
to
Action
under
error
code
25A80xxx.
25A8
0012
Data
corruption
detected,
some
data
partitions
may
have
been
preserved.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0100
NVRAM
data
validation
check
failed.
Turn
off,
turn
on
system
unit
and
retry
the
operation
before
replacing
any
system
component.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0201
Unable
to
expand
target
partition
-
Saving
configuration
variable.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0202
Unable
to
expand
target
partition
-
Writing
error
log
entry.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0203
Unable
to
expand
target
partition
-
Writing
VPD
data.
Refer
to
Action
under
error
code
25A80xxx.
25A8
0210
Setenv/$Setenv
parameter
error
-
name
contains
a
null
character.
Refer
to
Action
under
error
code
25A80xxx.
202
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......