Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
4069
3285
Memory
test
detected
PCI
controller
PHB1
1.
RIO
bus
adapter
Location:
U0.1-P1.1
2.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
4069
3286
Memory
test
detected
PCI
controller
PHB2
1.
RIO
bus
adapter
Location:
U0.1-P1.1
2.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
406A
0001
Self
test
detected
CEC
backplane
failure
CEC
backplane
Location:
U1.1-P1
406A
0003
Self
test
detected
processor
fault
All
processors
Location:
U1.1-P1-C1
406A
0009
Self
test
detected
memory
fault
All
memory
Location:
U1.1-P1-M1
x2
406A
00A0
Self
test
detected
CSP
service
processor
firmware
fault
Update
system
firmware
Location:
U0.1-P1/Y1
406A
00A1
Self
test
detected
AIX
or
system
firmware
fault
1.
Check
for
AIX
updates
2.
Check
for
system
firmware
updates
Location:
U0.1-P1/Y1
406A
00A2
Self
test
detected
service
processor
firmware
(processor
runtime
diagnostics)
fault
Check
for
system
firmware
updates
Location:
U0.1-P1/Y1
406A
00A3
Self
test
detected
memory
plugging
fault
All
pluggable
memory
406A
00A4
Self
test
detected
application
caused
fault
Application
software
406A
00A5
Self
test
detected
invalid
system
configuration
Verify
system
components
are
supported
and
properly
installed.
406A
00A6
Self
test
detected
no
usable
memory
1.
Ensure
that
CEC
memory
is
properly
installed.
2.
If
more
than
one
DIMM
is
called
out,
go
to
the
service
processor
Memory
Configuration/Deconfiguration
Menu
to
verify
memory
DIMMs
state.
See
″
Memory
Configuration/Deconfiguration
Menu
″
on
page
374
for
more
information.
406A
00A7
Self
test
detected
hardware
problem
Go
to
minimum
configuration
and
also
run
CEC
minimum
configuration
406A
00B0
Self
test
detected
bus
controller
lock-unlock
failure
RIO
bus
adapter
Location:
U0.1-P1.1
406A
00B1
Self
test
detected
bus
controller
failure
RIO
bus
adapter
Location:
U0.1-P1.1
406A
00B3
Self
test
detected
clock
fault
1.
Clock
card
Location:
U1.1-P1.1.1
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
Chapter
5.
Error
Code
to
FRU
Index
235
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......