![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 358](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775358.webp)
Table
9.
Common
Firmware
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
B1FD
0016
Diskette
read
error
1.
The
firmware
diskette
may
be
faulty.
Try
another
diskette.
2.
Replace
the
diskette
drive.
3.
Replace
the
primary
I/O
backplane.
B1FD
001A
Service
processor
firmware
update
fault
Reset
the
service
processor
with
the
pinhole
reset
or
by
disconnecting
then
reconnecting
power.
B1FD
001E
System
firmware
update
Fault
Wrong
system
firmware
update
diskette.
Insert
correct
diskette.
B1FD
001F
Bad
diskette
Replace
diskette
B1xx
0013
A
firmware
update
has
failed
because
the
update
image
is
invalid.
The
update
was
aborted
before
any
changes
were
made
to
the
currently
installed
firmware.
Install
a
valid
firmware
update
image
for
the
specific
system
type
and
model.
B1xx
4600
Service
processor
error
Primary
I/O
drawer
backplane
Location:
U0.1-P1
B1xx
4601
CPU
subsystem
problem
No
isolation
possible,
contact
next
level
of
support.
B1xx
4602
RIO
bus
fault
1.
Check/reseat
RIO
cables
2.
RIO
bus
adapter
Location:
U0.1-P1.1
3.
CEC
RIO
adapter
Location:
U1.1-P1.1
B1xx
4603
CSP
firmware
corrupted
1.
Reload
system
firmware
2.
Primary
I/O
backplane
Location:
U0.1-P1
B1xx
4606
Firmware
failure
1.
Check
for
system
firmware
updates
Location:
U0.1-P1/Y1
2.
Primary
I/O
drawer
operator
panel
Location:
U0.1-L1
3.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
B1xx
4608
CSP
early
termination
1.
Reset
the
system
by
disconnecting
and
reconnecting
system
power
2.
Reload
system
firmware
3.
Primary
I/O
backplane
Location:
U0.1-P1
B1xx
460A
TOD
clock
has
been
reset
1.
Set
TOD
Clock
2.
Primary
I/O
Drawer
Backplane
Location:
U0.1-P1
B1xx
460B
TOD
battery
failure
Replace
TOD
battery
Location:
U0.1-P1-V3
B1xx
4611
Service
processor
fault
1.
Primary
I/O
drawer
backplane
Location:
U0.1-P1
2.
Processor
card
Locations:
U1.1-P1-C1
U1.1-P1-C2
340
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......