If
the
ring-indicate
power-on
setting
is
changed,
you
must
select
option
30
(Refresh
Modem
Settings)
to
update
the
modem
settings.
If
option
30
(Refresh
Modem
Setting)
is
selected,
and
the
modem(s)
have
not
been
configured,
you
will
be
asked
to
configure
the
modems
first.
See
“Call-In/Call-Out
Setup
Menu”
on
page
380
for
information
on
configuring
modems.
Option
2
is
used
to
set
the
number
of
rings.
Note:
In
order
for
the
ring-indicate
power-on
settings
to
take
effect
and
ring-indicate
power-on
to
be
enabled,
the
service
processor
menus
must
be
exited
completely.
Enter
99
at
the
Main
Menu
screen
to
completely
exit
the
service
processor
menus.
v
Reboot/Restart
Policy
Setup
Menu
The
following
menu
controls
reboot/restart
policy:
Reboot/Restart
Policy
Setup
Menu
1.
Number
of
reboot
attempts:
Currently
1
2.
Use
OS-Defined
restart
policy?
Currently
Yes
3.
Enable
supplemental
restart
policy?
Currently
No
4.
Call-Out
before
restart:
Currently
Disabled
98.
Return
to
Previous
Menu
1>
Reboot
is
the
process
of
bringing
up
the
system
hardware;
for
example,
from
a
system
reset
or
power
on.
Restart
is
activating
the
operating
system
after
the
system
hardware
is
re-initialized.
Restart
must
follow
a
successful
reboot.
–
Number
of
reboot
attempts
-
If
the
server
fails
to
successfully
complete
the
boot
process,
it
attempts
to
reboot
the
number
of
times
specified.
Values
equal
to
or
greater
than
0
are
valid.
Only
successive
failed
reboot/restart
attempts
are
counted.
–
Use
OS-Defined
restart
policy
-
Allows
the
service
processor
to
react
or
not
react
in
the
same
way
as
the
operating
system
to
major
system
faults
by
reading
the
setting
of
the
operating
system
parameter
Automatically
Restart/Reboot
After
a
System
Crash
.
This
parameter
may
or
may
not
be
defined,
depending
on
the
operating
system
or
its
version/level.
If
the
operating
system
automatic
restart
setting
is
defined,
then
it
can
be
set
to
respond
to
a
major
fault
by
restarting
or
by
not
restarting.
See
your
operating
system
documentation
for
details
on
setting
up
operating
system
automatic
restarts.
The
default
value
is
Yes.
Chapter
8.
Using
the
Service
Processor
369
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......