Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406C
0224
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
14,
riser
1
Location:
U1.1-P1-M1.14
406C
0225
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
21,
riser
1
Location:
U1.1-P1-M1.21
406C
0226
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
22,
riser
1
Location:
U1.1-P1-M1.22
406C
0227
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
29,
riser
1
Location:
U1.1-P1-M1.29
406C
0228
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
30,
riser
1
Location:
U1.1-P1-M1.30
406C
022D
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
octal
C,
riser
1
Locations:
U1.1-P1-M1.5
x8
406C
022E
IPL
MOPS
detected
memory
DIMM
group
pair
A
fault
Memory
quad
C
odd,
riser
1
Locations:
U1.1-P1-M1.5
x4
406C
022F
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
quad
C
even,
riser
1
Locations:
U1.1-P1-M1.6
x4
406C
0231
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
7,
riser
1
Location:
U1.1-P1-M1.7
406C
0232
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
8,
riser
1
Location:
U1.1-P1-M1.8
406C
0233
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
15,
riser
1
Location:
U1.1-P1-M1.15
406C
0234
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
16,
riser
1
Location:
U1.1-P1-M1.16
406C
0235
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
23,
riser
1
Location:
U1.1-P1-M1.23
406C
0236
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
24,
riser
1
Location:
U1.1-P1-M1.24
406C
0237
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
31,
riser
1
Location:
U1.1-P1-M1.31
406C
0238
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
32,
riser
1
Location:
U1.1-P1-M1.32
406C
023D
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
octal
D,
riser
1
Location:
U1.1-P1-M1.7
x8
406C
023E
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
quad
D
odd,
riser
1
Location:
U1.1-P1-M1.7
x4
406C
023F
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
quad
D
even,
riser
1
Location:
U1.1-P1-M1.8
x4
406C
02FF
IPL
MOPS
detected
memory
on
riser
fault
All
memory
on
riser
1
Location:
U1.1-P1-M1.1
x32
Memory
failure
on
riser
card
1
that
cannot
be
automatically
isolated.
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
and
run
CEC
drawer
minimum
configuration
for
further
isolation.
406C
0300
IPL
MOPS
detected
processor
card
fault
Processor
card
Location:
U1.1-P1-C1
250
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......