![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 214](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775214.webp)
Table
6.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
20D0
0xxx
Unknown/unrecognized
device
20D0
000F
Selftest
failed
on
device,
no
error
and/or
location
code
information
available
Refer
to
“Determining
Location
Code”
on
page
160
to
see
if
a
location
code
is
available
for
the
device
the
error
was
reported
against.
1.
Replace
device
indicated
by
the
location
code
(if
available).
2.
Go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
20D0
0010
Selftest
failed
on
device,
can’t
locate
package
Contact
your
service
support
representative
for
assistance.
20D0
0011
Firmware
RTAS
attempt
to
allocate
memory
failed.
Contact
your
next
level
of
support
for
assistance.
20E0
0xxx
Security
20E0
0001
Privileged-access
password
entry
error.
The
password
has
been
entered
incorrectly.
Retry
installing
the
password.
20E0
0004
Battery
drained
or
needs
replacement
1.
Replace
battery
Location:
U0.1-P1-V3
2.
Replace
Primary
I/O
drawer
backplane
Location:
U0.1-P1
20E0
0009
Invalid
password
entered
-
system
locked
The
password
has
been
entered
incorrectly
3
times.
Turn
off,
then
turn
on
the
system
unit,
then
enter
the
password
correctly.
20EE
0xxx
Informational
20EE
0003
IP
parameter
requires
3
dots
″
.
″
Enter
valid
IP
parameter.
Example:
000.000.000.000
20EE
0004
Invalid
IP
parameter
Enter
valid
IP
parameter.
Example:
000.000.000.000
20EE
0005
Invalid
IP
parameter
(>255)
Enter
valid
IP
parameter.
Example:
255.192.002.000
20EE
0006
No
recognized
SCSI
adapter
present
This
warning
occurs
when
the
selected
SMS
function
cannot
locate
any
SCSI
adapter
supported
by
the
function.
If
a
supported
SCSI
adapter
is
installed:
1.
Replace
SCSI
adapter(s).
2.
Replace
the
I/O
drawer
backplane
in
drawer(s)
containing
SCSI
adapter(s).
20EE
0007
Keyboard
not
found
1.
Plug
in
keyboard.
2.
Replace
primary
I/O
drawer
backplane
Location:
U0.1-P1
196
Service
Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......