![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 245](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775245.webp)
Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
4068
0534
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
16,
riser
2
Location:
U1.1-P1-M2.16
4068
0535
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
23,
riser
2
Location:
U1.1-P1-M2.23
4068
0536
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
24,
riser
2
Location:
U1.1-P1-M2.24
4068
0537
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
31,
riser
2
Location:
U1.1-P1-M2.31
4068
0538
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
32,
riser
2
Location:
U1.1-P1-M2.32
4068
053D
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
octal
D,
riser
2
Location:
U1.1-P1-M2.7
x8
4068
053E
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
D
odd,
riser
2
Location:
U1.1-P1-M2.7
x4
4068
053F
Other
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
D
even,
riser
2
Location:
U1.1-P1-M2.8
x4
4068
05FF
Other
bus
processor
runtime
diagnostics
detected
memory
on
riser
fault
Memory
failure
on
riser
card
2
that
cannot
be
automatically
isolated.
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
and
run
CEC
drawer
minimum
configuration
for
further
isolation.
4068
0600
Other
bus
processor
runtime
diagnostics
detected
CEC
RIO
bus
adapter
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
0601
Other
bus
processor
runtime
diagnostics
detected
clock
card
fault
CEC
clock
card
Location:
U1.1-P1.1.1
4068
3101
Other
bus
processor
runtime
diagnostics
detected
RIO
port
0
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
3102
Other
bus
processor
runtime
diagnostics
detected
RIO
port
1
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
3103
Other
bus
processor
runtime
diagnostics
detected
RIO
port
2
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
3104
Other
bus
processor
runtime
diagnostics
detected
RIO
port
3
fault
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
3121
Other
bus
processor
runtime
diagnostics
detected
RIO
cable
on
port
0
fault
1.
RIO
cable
on
port
0
Location:
U1.1-P1.1/Q1
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
3122
Other
bus
processor
runtime
diagnostics
detected
RIO
cable
on
port
1
fault
1.
RIO
cable
on
port
1
Location:
U1.1-P1.1/Q2
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
4068
3123
Other
bus
processor
runtime
diagnostics
detected
RIO
cable
on
port
2
fault
1.
RIO
cable
on
port
2
Location:
U1.1-P1.1/Q3
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
Chapter
5.
Error
Code
to
FRU
Index
227
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......