Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406C
0203
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
9,
riser
1
Location:
U1.1-P1-M1.9
406C
0204
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
10,
riser
1
Location:
U1.1-P1-M1.10
406C
0205
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
17,
riser
1
Location:
U1.1-P1-M1.17
406C
0206
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
18,
riser
1
Location:
U1.1-P1-M1.18
406C
0207
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
25,
riser
1
Location:
U1.1-P1-M1.25
406C
0208
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
26,
riser
1
Location:
U1.1-P1-M1.26
406C
020D
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
octal
A,
riser
1
Location:
U1.1-P1-M1.1
x8
406C
020E
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
quad
A
odd,
riser
1
Locations:
U1.1-P1-M1.1
x4
406C
020F
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
quad
A
even,
riser
1
Locations:
U1.1-P1-M1.2
x4
406C
0211
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
3,
riser
1
Location:
U1.1-P1-M1.3
406C
0212
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
4,
riser
1
Location:
U1.1-P1-M1.4
406C
0213
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
1
Location:
U1.1-P1-M1.11
406C
0214
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
1
Location:
U1.1-P1-M1.12
406C
0215
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
19,
riser
1
Location:
U1.1-P1-M1.19
406C
0216
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
20,
riser
1
Location:
U1.1-P1-M1.20
406C
0217
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
27,
riser
1
Location:
U1.1-P1-M1.27
406C
0218
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
28,
riser
1
Location:
U1.1-P1-M1.28
406C
021D
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
octal
B,
riser
1
Location:
U1.1-P1-M1.3
x8
406C
021E
IPL
MOPS
detected
memory
DIMM
group
pair
A
fault
Memory
quad
B
odd,
riser
1
Location:
U1.1-P1-M1.3
x4
406C
021F
IPL
MOPS
detected
memory
DIMM
group
fault
Memory
quad
B
even,
riser
1
Location:
U1.1-P1-M1.4
x4
406C
0221
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
5,
riser
1
Location:
U1.1-P1-M1.5
406C
0222
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
6,
riser
1
Location:
U1.1-P1-M1.6
406C
0223
IPL
MOPS
detected
memory
DIMM
fault
Memory
DIMM
13,
riser
1
Location:
U1.1-P1-M1.13
Chapter
5.
Error
Code
to
FRU
Index
249
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......