![IBM RS/6000 Enterprise Server M80 Service Manual Download Page 249](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775249.webp)
Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
4069
022D
Memory
test
detected
memory
DIMM
group
fault
Memory
octal
C,
riser
1
Locations:
U1.1-P1-M1.5
x8
4069
022E
Memory
test
detected
memory
DIMM
group
pair
A
fault
Memory
quad
C
odd,
riser
1
Locations:
U1.1-P1-M1.5
x4
4069
022F
Memory
test
detected
memory
DIMM
group
fault
Memory
quad
C
even,
riser
1
Locations:
U1.1-P1-M1.6
x4
4069
0231
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
7,
riser
1
Location:
U1.1-P1-M1.7
4069
0232
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
8,
riser
1
Location:
U1.1-P1-M1.8
4069
0233
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
15,
riser
1
Location:
U1.1-P1-M1.15
4069
0234
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
16,
riser
1
Location:
U1.1-P1-M1.16
4069
0235
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
23,
riser
1
Location:
U1.1-P1-M1.23
4069
0236
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
24,
riser
1
Location:
U1.1-P1-M1.24
4069
0237
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
31,
riser
1
Location:
U1.1-P1-M1.31
4069
0238
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
32,
riser
1
Location:
U1.1-P1-M1.32
4069
023D
Memory
test
detected
memory
DIMM
group
fault
Memory
octal
D,
riser
1
Location:
U1.1-P1-M1.7
x8
4069
023E
Memory
test
detected
memory
DIMM
group
fault
Memory
quad
D
odd,
riser
1
Location:
U1.1-P1-M1.7
x4
4069
023F
Memory
test
detected
memory
DIMM
group
fault
Memory
quad
D
even,
riser
1
Location:
U1.1-P1-M1.8
x4
4069
02FF
Memory
test
detected
memory
on
riser
fault
All
memory
on
riser
1
Location:
U1.1-P1-M1.1
x32
Memory
failure
on
riser
card
1
that
cannot
be
automatically
isolated.
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
and
run
CEC
drawer
minimum
configuration
for
further
isolation.
4069
0300
Memory
test
detected
processor
card
fault
Processor
card
Location:
U1.1-P1-C1
4069
0400
Memory
test
detected
processor
card
fault
Processor
card
Location:
U1.1-P1-C2
4069
0500
Memory
test
detected
memory
riser
card
fault
Memory
riser
card
2
Location:
U1.1-P1-M1
4069
0501
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
1,
riser
2
Location:
U1.1-P1-M2.1
4069
0502
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
2,
riser
2
Location:
U1.1-P1-M2.2
4069
0503
Memory
test
detected
memory
DIMM
fault
Memory
DIMM
9,
riser
2
Location:
U1.1-P1-M2.9
Chapter
5.
Error
Code
to
FRU
Index
231
Summary of Contents for RS/6000 Enterprise Server M80
Page 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 16: ...xvi Service Guide...
Page 22: ...Data Flow 4 Service Guide...
Page 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Page 84: ...66 Service Guide...
Page 176: ...158 Service Guide...
Page 376: ...358 Service Guide...
Page 430: ...412 Service Guide...
Page 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Page 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Page 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Page 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Page 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Page 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Page 508: ...490 Service Guide...
Page 520: ...502 Service Guide...
Page 522: ...504 Service Guide...
Page 526: ...508 Service Guide...
Page 558: ...540 Service Guide...
Page 565: ......