6 - 34
11. WHEN SAFETY SOLENOID DOES NOT OPERATE
ş
Before disconnecting the connector, always turn the starting switch OFF.
ş
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No.8.
ş
After checking, insert the disconnected connectors again immediately unless otherwise specified.
X
2
CS-4
H
CN-2
FUSE
NO.8
A
1
SAFETY SOLENOID
CN-68
SAFETY SWITCH
3
2
1
3
2
1
Cause
Remedy
Hydraulic malfunction
Defective solenoid
Defective switch
Disconnection in wiring
harness or poor
contact between
CS-4(3)-CN-68(2)
Disconnect in wiring
harness or poor
contact between
CN-2(X)-CN-68(2)
Disconnection in
fuse
Check hydraulic
system
Replace
Check and
replace
Repair or replace
Repair or replace
Replace
NO
NO
Check voltage
between CN-68(1)
- CN-68(2)
YES
NO
YES
Safety lever : OFF
Starting switch : ON
Voltage : 20~30V
NO
Check operation
of solenoid
Safety lever : ON-OFF
YES
YES
NO
Starting switch : ON
Voltage : 20~30V
Disconnect CN-2
Start switch : ON
Voltage : 20~30V
Disconnect CN-2
Starting switch : ON
Voltage : 20~30V
Safety state
Check voltage
between CN-68(2)
with chassis
Check voltage
between CS-4(3)
and chassis
Check voltage
between CN-2(X)
and chassis
YES
Summary of Contents for R 160 LC-3
Page 9: ......
Page 142: ...4 4...
Page 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Page 397: ......
Page 398: ......
Page 399: ......
Page 400: ......
Page 401: ......
Page 402: ......
Page 403: ......
Page 404: ......
Page 405: ......
Page 406: ......
Page 407: ......
Page 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Page 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Page 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...