6 - 31
8. WHEN COOLANT LEVEL LAMP LIGHTS UP(Engine is started)
ş
Before disconnecting the connector, always turn the starting switch OFF.
ş
Before carrying out below procedure, check all the related connectors are properly inserted.
ş
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Insufficient coolant
or Defective switch
Short circuit
Defective controller
Refill coolant or
replace switch
Check and repair
Replace
CN-50
18
CD-16
1
2
COOLANT LEVEL SENSOR
CONTROLLER
NO
YES
YES
NO
Starting switch : ON
Engine : Start
Does display go off
when disconnect
CD-16?
Check resistance
between CN-50
(18) and chassis
Starting switch : OFF
Disconnect CN-50
YES
NO
MAX 1
װ
MIN 1M
װ
Check resistance
Summary of Contents for R 160 LC-3