6 - 56
YES
YES
Wiring diagram
SPEC
KEY ON : 24
Ź
1V
KEY OFF : 0V
See TEST 14
SPEC: 15-30
װ
See TEST 14
NO
SPEC : Power max button pressed ON : 0
װ
Power max button released OFF :
ſװ
See TEST 15
Is voltage between
CN-88(1) -GND
normal?
Resistance
between CN-50
(21) -GND normal?
Check resistance
between CN-88
(1) - (2)
Defective power
max. solenoid valve
Short circuit or poor
connection between
CN-50(21) - CS-
29 and CN-53(10) -
CN-88(1)
Short circuit or poor
connection between
CN-88(1)-battery
relay(+)
Repair or replace
Repair or replace
Repair or replace
NO
8. MALFUNCTION OF POWER MAX
Before carrying out below procedure, check all the related connectors are properly inserted.
INSPECTION PROCEDURE
Ɠ
1)
POWER MAX SOLENOID
CS-29
10
CN-53
CPU CONTROLLER
21
CN-50
POWER MAX SWITCH
2
FUSE
NO.6
1
CN-88
U
CN-2
Cause
Remedy