6 - 48
TEST PROCEDURE
Test 9 : Check electric current at EPPR
valve at F-mode
Install multimeter as figure.
Start engine.
Set F-mode with 1750
Ź
50rpm.
Check electric current.
CN-75
Multimeter
EPPR VALVE
CN-75
Supply line, pilot press
Pressure adjusting
screw locknut
(1)
ڸ
ڹ
ں
ڻ
2)
Test 10 : Check pressure at EPPR valve
at F-mode
Connect pressure gauge at EPPR valve.
Start engine.
Set F-mode with 1750
Ź
50rpm.
Operate bucket lever completely push or
pull.
Hold arm lever at the end of stroke.
Check pressure at relief position.
(2)
ڸ
ڹ
ں
ڻ
ڼ
ڽ
SPEC : 400~500mA
SPEC : 15~25kgf/cm
2
(218~363psi)