5 - 25
3. EPPR VALVE CHECK PROCEDURE
CHECK ELECTRIC VALUE AT EPPR VALVE
Start engine.
Set S-mode and cancel auto decel mode.
If tachometer show approx 2250
Ź
50rpm,
disconnect one wire harness from EPPR
valve.
Install multimeter as figure.
Check electric current at bucket circuit
relief position.
CHECK PRESSURE AT EPPR VALVE
Remove plug and connect pressure
gauge as figure.
Gauge capacity : 0 to 40-50kgf/cm
2
(0 to 570-710psi)
Start engine.
Set S-mode and cancel auto decel mode.
If tachometer show approx 2250
Ź
50rpm.
Check pressure at relief position of bucket
circuit by operating bucket control lever.
If pressure is not correct, adjust it.
After adjust, test the machine.
CN-75
Multimeter
EPPR VALVE
CN-75
Supply line, pilot press
Pressure adjusting
screw
locknut
(1)
(2)
(3)
(4)
(5)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
1)
2)
Spec : 200~400mA
Spec : 2~10kgf/cm
2
(30~140psi)