6 - 52
CN-50
CPU
CONTROLLER
CN-51
CN-52
CN-53
15
12
11
10
9
1
2
3
17 18 19
Multimeter
CN-50
20 21 22
4
5
6
13 14
7
8
16
23 24
Test 12 : Check voltage and resistance.
Check resistance between CN-50(14)-
(22).
Starting key OFF.
Disconnect connector CN-50 from CPU
controller.
Check resistance value with multimeter
as figure.
(2)
ڸ
,
,
,
Check voltage between CN-50(6) and
CN-50(22).
Prepare 2 pieces of thin sharp pin, steel
or copper.
Starting key ON.
Insert prepared pins to rear side of
connectors : One pin to CN-50(6)
Other pin to CN-50(22)
Check voltage.
ڹ
,
,
,
,
SPEC : 0.1~0.9k
װ
15
CN-50
12
11
10
9
1
2
3
17 18 19
Multimeter
CN-50
20 21 22
4
5
6
13 14
7
8
16
23 24
PIN
CPU
CONTROLLER
CN-51
CN-52
CN-53
SPEC : 5
Ź
1V
Summary of Contents for R 160 LC-3
Page 9: ......
Page 142: ...4 4...
Page 182: ...4 44 No of pin Receptacle connector Female Plug connector Male 24 12 24 1 13 S815 024000...
Page 397: ......
Page 398: ......
Page 399: ......
Page 400: ......
Page 401: ......
Page 402: ......
Page 403: ......
Page 404: ......
Page 405: ......
Page 406: ......
Page 407: ......
Page 416: ...8 103 Remove lock nut 21 and then boot 26 15...
Page 427: ...8 114 Install cover 3 to hub 1 and tighten bolts 14 Torque 5 5 12 5kgf m 40 90lbf ft 7 14 15 3...
Page 456: ...8 143 1 STRUCTURE GROUP 11 WORKEQUIPMENT SECTION A SECTION B SECTION C C B B A A C...